EPA secondary containment requirements are among the most misunderstood regulations in industrial facility management. Facility managers often know they need secondary containment but are unclear on exactly what triggers the requirement, what qualifies as compliant containment, and what the consequences of non-compliance look like.
This guide covers the core EPA requirements for secondary containment at industrial facilities and what you need to know to build a compliant program.
What Is Secondary Containment
Secondary containment is a physical barrier system designed to catch and hold liquid in the event that a primary container, such as a tank, drum, or tote, fails or leaks. The purpose is to prevent spilled liquid from reaching the ground, stormwater systems, or navigable waters.
Secondary containment can take many forms including concrete berms, earthen dikes, containment pallets, flexible berms, and portable containment systems. The right solution depends on the volume of liquid being contained, the chemical nature of the material, and the facility layout.
When Secondary Containment Is Required
EPA secondary containment requirements apply under several regulatory programs depending on the type of material stored and the quantity involved.
SPCC Plans (Spill Prevention, Control, and Countermeasure)
Facilities that store oil above certain threshold quantities above ground are required to develop and implement an SPCC Plan under 40 CFR Part 112. The thresholds are 1,320 gallons of aboveground oil storage capacity, or 42,000 gallons of completely buried oil storage. Facilities subject to SPCC must have secondary containment for all oil storage containers with capacity of 55 gallons or more.
RCRA Hazardous Waste
Facilities that generate, store, or treat hazardous waste under RCRA are subject to secondary containment requirements for storage containers and tanks. The specific requirements depend on the quantity of waste generated and the storage method.
Clean Water Act
Facilities with the potential to discharge pollutants to waters of the United States may be required to implement containment measures under NPDES permits. Stormwater permits often include requirements for containment structures around materials that could contaminate runoff.
What Qualifies as Compliant Secondary Containment
For SPCC purposes, secondary containment must meet the following basic standards:
- Sufficient capacity to hold the contents of the largest single container plus precipitation. For a single container, the containment must hold 110% of the container volume. For multiple containers, it must hold 110% of the largest container or 10% of the aggregate volume, whichever is greater.
- Constructed of materials compatible with the stored liquid
- No drain valves or openings that would allow spilled material to escape
- Maintained in good condition and inspected regularly
Portable containment systems including flexible berms can qualify as compliant secondary containment when properly sized and maintained. Spill Bully L-Bracket Berms and Drive-Over Foam Wall Berms are used by facilities across a range of industries as compliant secondary containment solutions for drums, totes, generators, and equipment.
Common Compliance Gaps
EPA inspectors and SPCC auditors frequently find the same compliance gaps at facilities that believe they are covered:
Undersized containment
The 110% rule is often misapplied. Facilities calculate based on nominal drum or tote capacity rather than the actual maximum fill volume, or fail to account for precipitation accumulation in outdoor containment structures.
Incompatible materials
Containment structures made from materials that can be degraded by the stored liquid are a compliance gap and a practical failure point. Chemical compatibility matters for both regulatory compliance and real-world performance.
Drain valves left open
Containment structures with drain valves that are left open or unsecured defeat the purpose of the containment entirely and are a common finding in inspections.
No inspection records
SPCC requires documented regular inspections of containment structures. Facilities with physical containment but no inspection records are out of compliance even if the hardware is correct.
Portable vs Permanent Containment
Permanent concrete berms and earthen dikes are the traditional approach to secondary containment but they are expensive, inflexible, and not always practical in a working facility. Portable flexible containment systems have become widely accepted by regulators as compliant alternatives when properly sized and maintained.
Portable containment offers several practical advantages: it can be repositioned as facility layouts change, it requires no construction permitting, and it can be sized precisely for the containers being protected rather than overbuilt to accommodate a fixed structure.
Spill Bully secondary containment berms are available in custom sizes from 2 by 2 feet up to 12 by 60 feet with capacities from under 10 gallons to over 4,000 gallons. Custom sizes are available for any footprint.
Browse Spill Bully secondary containment solutions or contact us to configure containment for your facility.